Solar DC surge protector calculator: which voltage rating?

Enter the panels per string, the open circuit voltage from the panel's datasheet, its temperature coefficient and the coldest morning on site. The calculator gives the string voltage at that temperature and the DC surge device rating to look for.

Solar DC surge protector calculatorString voltage on a cold morning and the DC surge device rating to ask for
Sheet
SSPC-01
Method
Ucpv

The figures update as you type. A guide for planning and briefing, not a design.

Drawing

String Voc at 25 °C
-
String Voc on the coldest dawn
-
1.2 x Voc rule
-
Against the inverter limit
-
DC SPD rating UCPV to ask for
-

A DC surge protection device (SPD) for a solar array must be rated above the highest voltage the string can ever produce. That is the open circuit voltage on a cold, bright morning: solar panels give more voltage the colder they are, and on the Highveld a winter dawn below freezing can push a string well above its datasheet figure.

How it works

String voltage at standard conditions. Voc string = panels per string x Voc of one panel (at 25 °C).

On the coldest morning. Voc(T) = Voc string x [1 + β / 100 x (T minus 25)], where β is the panel's temperature coefficient of Voc in percent per degree (a negative number, often about minus 0.25 to minus 0.30 for current panels) and T the lowest cell temperature, taken as the lowest air temperature at dawn.

The SPD rating. A common rule for PV SPDs is a maximum continuous DC voltage UCPV of at least 1.2 times the string's Voc at standard conditions. The calculator also checks the cold morning figure and picks the next common rating above the higher of the two: 600, 800, 1,000, 1,200 or 1,500 V DC.

Type 1 or type 2?

If the building has an external lightning protection system, or the array is exposed and could take a direct strike, the DC side usually gets a type 1 (or combined type 1+2) device. Otherwise type 2 is common. Fit SPDs at the inverter end of each string and, for long cable runs of more than about 10 m, at the array end too, with AC surge protection on the inverter's output and at the DB. See DC surge protection and solar panel lightning protection.

Frequently asked questions

Where do I find the temperature coefficient?
On the panel's datasheet, under temperature characteristics, as the temperature coefficient of Voc (sometimes written as beta). It is a negative percentage per degree, for example minus 0.27 % per °C.
What lowest temperature should I use?
The lowest dawn air temperature the site is likely to see. Parts of the Highveld and Free State go below minus 5 °C in winter; the coast seldom drops below freezing. If in doubt, use a colder figure.
Does the inverter limit matter too?
Yes. The same cold morning voltage must stay under the inverter's maximum DC input voltage. If the calculator shows a figure close to the inverter's limit, the string is too long and the installer should take a panel out.

Sources

Formulas and table values as published in these standards and papers. The calculators simplify them for a first look; a designer applies the full method.

More calculators

Free quote request, no obligation

Request quotes for DC surge protection

Fill in the survey sheet the way an installer would on a first visit: the size and height of the building, the roof and the protection class if you know it, or simply how many arresters, plugs, spikes, metres or visits. Installers and suppliers in your area quote you directly.

Site survey sheetDC Surge Protection for Solar
Sheet
68736
Date
2026-11-21
Scale
NTS

1The job

2How many (optional, it helps the quote)

Your ordernot to scale

-
-
-
-
-
-
Estimate
-

Geometry and the standard's table figures for the request, not a design.

3Where you are now

4Your list (optional)

  1. 01
  2. 02
Up to 12 lines: rods, masts, arresters, spikes, tape or services.
Needs and options

5Your details

Free and no obligation. By sending you agree that we may share your request with suitable installers, electricians, engineers and suppliers. See our privacy policy.

Get free lightning protection quotes